Ask HN: MagSafe Equivalent for Wall Outlets?
I am looking for a similar experience to Magsafe connectors, but for anything that plugs to my wall outlets. I find constantly connecting and disconnecting devices that share outlets (in my bathroom alone I have an electric toothbrush, a hair blower, and an electric shaver) and I'd really wish it was as easy to disconnect and connect as my Macbook Air's Magsafe adapter.
Now, I looked around and can't find a single product for this other than this one [0] made by a product studio in Oregon which is out of stock (also can't find any reviews online so can't tell if it ever shipped).
The idea feels obvious so I'm surprised no one has done it. I don't think there are any laws of physics that would make this impossible? Is it a case of a patent or regulations blocking this?
I'm sure the Magsafe engineers at Apple have thought of this :)
[0] - https://ilovehandles.com/shop/tug/
Comments
The live end has to be inaccessible to fingers, unlike the low voltage contacts on the MagSafe. Done.
But the line voltage prongs need to make solid contact with only the pressure of the magnet holding them in. The more gripping force, the more likely you'd trip on the cord. To me, that's the limiting factor.
A "trip sensor" like a garage door or safety table saw might have would add to the complexity.
I can check the code book, but there's a reason that plugs and outlets are snug, and you replace ones that aren't. A firm connection is a safe one.
NEC now requires Arc-Fault Circuit Interrupter. Wikipedia [0] says:
Reason for the code requirement: [1]
Quite possibly, arc fault breakers present the cheapest fire insurance you can give your home.
[0] https://en.wikipedia.org/wiki/Arc-fault_circuit_interrupter
[1] https://www.protoolreviews.com/what-is-arc-fault-circuit-bre...
OTOH, countertop deep dryers have had magsafe-like connectors for their power cords for a long time (I seem to remember seeing them before Apple's version, but I could be misremembering). That cord is carrying wall current. The purpose of them is so that if you snag the power cord or little hands give it a yank, it will disconnect before the fryer can be pulled off a counter or tip over.
My countertop water heater power cord does the same thing. It's kinda annoying, because just moving the boiler around the counter will often cause it to come loose: https://shop.zojirushi.com/products/8-cdp-p300
That goes from the wall outlet directly into one of the boilers like this: https://shop.zojirushi.com/collections/water-boilers-warmers
WHOA! You made me look. I have a Krups deep fryer that I never use, because who fries food in oil any more? The plug has two magnets surrounded by cylindrical sockets that pins in the fryer go into.
It's good for 1700 watts at 120 volts. Meets UL Standard 1083, CSA C22.2 No.64.
If we haven't seen something like this yet, it must have to do with cost. It's about twice the width, with the two magnets, of the $20 unit.
I do. Fried chicken and donuts, mmmmmm. :)
I need to lose some weight. Yes, mmmmmmmmmmm.
This is an awesome reply, thank you so much for explaining this, and for the links!